Chapter 2. Gassy and Extrahazardous Tunnels
California Labor Code, § 7965 to § 7985. 21 sections.
- § 7965Any tunnel or underground mine classified by the division as gassy shall operate under special procedures adopted by the board, as well as rules, regulations, special orders, or general orders for nongassy underground mi…
- § 7966In any tunnel classified as gassy by the division, there shall be tests for gas or vapors taken prior to each shift and at least hourly during actual operation. If a mechanical excavator is used, gas tests shall be made …
- § 7967Whenever gas levels in excess of 10 percent of the lower explosive limit are encountered initially in a tunnel or underground mine classified as gassy, the division shall be notified immediately by telephone or telegraph…
- § 7968In any gassy tunnel or underground mine, the division may order work halted until adequate testing can be completed to determine the level of hazard from gases or vapors. A notice of such shutdown shall be filed by the d…
- § 7969In any gassy tunnel or underground mine the division shall review plans for electrical lighting and power for equipment. When it is necessary for safety, the inspector may require changes in the amount and type of lighti…
- § 7970In any tunnel or underground mine classified gassy, smoking shall be prohibited and the employer shall be responsible for collecting all personal sources of ignition such as lighters and matches from employees entering t…
- § 7971Whenever there is any ignition of gas or vapor in a tunnel or underground mine, all work shall cease, employees shall be removed, and reentry except for rescue purposes shall be prohibited until the division has conducte…
- § 7972If the level of gas in any tunnel or underground mine reaches 20 percent of its lower explosive limit at any time all men shall be removed, the division notified immediately by telephone or telegram, and no one shall ree…
- § 7973In any tunnel or underground mine classified as gassy, all employees shall be informed of any special orders made by the division following an inspection. Such notice shall be given before entering the tunnel or undergro…
- § 7974In any tunnel classified as gassy by the division, ventilation shall include continuous exhausting of fumes and air, unless an alternative ventilation plan which is as effective or better is approved by the division. Fan…
- § 7975A “kill” button capable of cutting off all electrical equipment shall be maintained in any gassy tunnel or underground mine. The safety representative or his designated representative shall cut off power at any time gas …
- § 7976In any tunnel or underground mine classified as gassy, the division shall determine the number of fire extinguishers necessary and their locations.
- § 7977Any tunnel or underground mine classified as extrahazardous by the division shall comply with the provisions for gassy tunnels in this chapter, as well as regulations, rules, special orders, and general orders of the div…
- § 7978In any extrahazardous tunnel or underground mine smoking by employees or open flame shall be prohibited. Welding or cutting with arc or flame underground in other than fresh air shall be done under the direct supervision…
- § 7979In tunnels or underground mines classified extrahazardous, sufficient air shall be supplied to maintain an atmosphere of all of the following conditions: (a) Not less than 19 percent oxygen. (b) Not more than 0.5 perce…
- § 7980All electrical equipment and machines, including diesel engines, used in tunnels or underground mines classified extrahazardous shall be permissible equipment. The division may, however, permit the use of nonpermissive e…
- § 7981An escape chamber or alternate escape route shall be maintained within 5,000 feet of the tunnel face or areas being used to excavate material in an underground mine classified as gassy or extrahazardous. Workers shall be…
- § 7982Records of air flow and air sample tests to assure compliance with required standards shall be maintained by the employer at the site of any tunnel or underground mine classified extrahazardous. Such records shall be mad…
- § 7983The main fan line used for ventilation in any tunnel or underground mine classified extrahazardous shall contain a cutoff switch capable of halting all machinery underground automatically should the fan fail or its perfo…
- § 7984In any tunnel or underground mine classified extrahazardous a device or devices which automatically and continuously test the atmosphere for gases or vapors shall be maintained. Such device or devices shall be placed as …
- § 7985All such testing device or devices shall be U.S. Bureau of Mines approved or acceptable to other authorities recognized by the division and shall automatically sound an alarm and activate flashing red signals visible to …